checking the AC on a Trane system

checking the AC on a Trane system

Shawn  L.

Shawn L. Job Checkin


Shawn  L.

Shawn L. Job Checkin


Shawn  L.

Shawn L. Job Checkin

Found the customers upstairs Carrier system low on R22 charge. Found a leak in the evaporator coil located in the attic. Discussed repair and replacement options.


Robert C.

Robert C. Job Checkin

installed rheem heatpump split

installed rheem heatpump split

Robert C.

Robert C. Job Checkin

replaced lennox evaporator coil

replaced lennox evaporator coil

Chad R.

Chad R. Job Checkin

replaced overflow drain pan underneath furnace that was leaking water.


Chad R.

Chad R. Job Checkin

Upstairs Goodman split AC. At arriva, found unit would not turn on. The drain pan and safety switch were both full of water. Drain line was not clogged. Ran system and found the reason for the failure is due to low refrigerant. this is causing the system to freeze over.

Upstairs Goodman split AC. 

At arriva, found unit would not turn on. The drain pan and safety switch were both full of water. Drain line was not clogged. 

Ran system and found the reason for the failure is due to low refrigerant. this is causing the system to freeze over.

Brian L.

Brian L. Job Checkin

AC Repair Service: Upon receiving complaints of poor cooling performance, I diagnosed and corrected insufficient refrigerant charge during my inspection. Correcting the refrigerant levels was essential for optimizing system operation and performance.


Chad R.

Chad R. Job Checkin

Appointment scheduled this morning 730-12. Arrived at 730 and knocked and rang doorbell. Waited 20 minutes and no answer. Will have to reschedule


Chad R.

Chad R. Job Checkin

Lennox split AC, whole house, two zone system. Tested system at arrival and found that it was completely out of refrigerant. Filled with nitrogen and searched for leaks and found that the evaporator coil is leaking. Could audibly hear the leak. Will have to replace the evap coil. Due to age and conditions all options should be explored Will submit information to AHS for authorization of repairs.

Lennox split AC, whole house, two zone system. 

Tested system at arrival and found that it was completely out of refrigerant.  Filled with nitrogen and searched for leaks and found that the evaporator coil is leaking. Could audibly hear the leak. 

Will have to replace the evap coil. Due to age and conditions all options should be explored 

Will submit information to AHS for authorization of repairs.

Shawn  L.

Shawn L. Job Checkin

No cool service call for the customers two zone Carrier system.


Shawn  L.

Shawn L. Job Checkin

Finished up performing a detailed maintenance on the customers two Carrier systems.

Finished up performing a detailed maintenance on the customers two Carrier systems.

Shawn  L.

Shawn L. Job Checkin

Performing a Island Breeze protection pledge maintenance on both the customers up and downstairs systems.

Performing a Island Breeze protection pledge maintenance on both the customers up and downstairs systems.